Report Overview
THE HOUSE IN PERSPECTIVE
This is a well built home.
As with all homes, ongoing maintenance is required and improvements to
the systems of the home will be needed over time. The improvements that are recommended in
this report are not considered unusual for a home of this age and location. Please remember that there is no such thing
as a perfect home.
  CONVENTIONS USED IN THIS REPORT
For your convenience, the following conventions have been
used in this report.
Major
Concern: a system or component which is considered significantly deficient
or is unsafe. Significant deficiencies need to be corrected and, except for
some safety items, are likely to involve significant expense.
Safety
Issue: denotes a condition that is
unsafe and in need of prompt attention.
Repair:
denotes a system or component which is missing or which needs corrective action
to assure proper and reliable function.
Improve: denotes improvements which are recommended
but not required.
Monitor: denotes a system or component needing further
investigation and/or monitoring in order to determine if repairs are necessary.
Please note that those observations listed under
“Discretionary Improvements” are not essential repairs, but represent logical
long term improvements.
·
For the purpose of this report, it
is assumed that the house faces south.
  IMPROVEMENT RECOMMENDATION
HIGHLIGHTS / summary
The following is a synopsis of the potentially significant
improvements that should be budgeted for over the short term. Other significant improvements, outside the
scope of this inspection, may also be necessary. Please refer to the body of this report for
further details on these and other recommendations.
All issues found in
this report should be addressed with the appropriate parties to make any
improvements, corrections or repairs necessary.
All improvements, corrections and repairs should meet the satisfaction
of the client named on this report and the inspection agreement associated with
this report prior to closing. This
report and the findings listed herein are intended for the client only and is not transferable without a signed written agreement.
Foundation
·
Monitor: Common minor
settlement cracks were observed in the foundation walls. This implies that some
structural movement of the building has occurred. Cracks of this type should be
watched for any sign of additional movement. In the absence of any sign of
ongoing movement, repair should not be necessary.
·
Monitor: The basement floor
slab has typical cracks for a house of this age. Cracks are very common and are not normally a
concern. Small portions of the floor
have been removed and should be filled.
Floors
·
Monitor: Minor unevenness
was observed in the floor structure. This condition is common. It may be the
result of the materials, framing design, installation methods and aging of the
building. There was not evidence of need for immediate, costly repair.
·
Monitor, Repair: Minor
unevenness was observed in the floor structure. This condition is common. It
may be the result of the materials, framing design, installation methods and
aging of the building. There was not evidence of need for immediate, costly
repair.
·
Recommend: Parging of the interior of the old foundation walls is
desirable to improve appearance and avoid further foundation damage.
Chimneys
·
Repair: The masonry chimney
needs re-pointing (replacing the mortar between the bricks) to avoid water
damage.
·
Recommend: A rain cap should
be installed on the masonry chimney and the chimney flue should be checked for
damage. Damaged flues can be unsafe.
Gutters & Downspouts
·
Repair: The downspout(s)
should discharge water at least five (5) feet from the house. Storm water
should be encouraged to flow away from the building at the point of
discharge. One on the west side does not
have an extension on it to direct water away from the building.
Exterior Walls
·
Monitor: Common minor cracks were observed on the
exterior wall on the west side. This implies that structural movement has
occurred. The location, size, shape of these cracks is common. The inspection
did not find evidence of significant movement requiring immediate major
repairs.
·
Monitor, Repair: Localized
damage at the base of the stucco exterior walls of the garage should be
repaired.
Garage
·
Repair, Safety Issue: The garage door opener did not
automatically reverse under resistance to closing. There is a serious risk of
injury, particularly to children, under this condition. The opener may need replacement.
·
Monitor, Safety Issue: Pronounced
floor cracks were noted in the garage. While this amount of cracking is
unusual, this slab is not a structural component you should be aware of the
trip hazard.
Driveway
·
Monitor: The driveway has
settled and cracked. Persisting movement
may result in the need for repairs.
Walkway
·
Recommend, Safety Issue: The
walkway presents a trip hazard. This condition should be altered for improved
safety.
Landscaping
·
Repair: Tree branches should
be kept trimmed away from the house to avoid damage to the building.
·
Repair: Shrubs/bushes
growing near exterior walls and vines growing on the exterior walls should be
kept trimmed away from siding, window trims, and the eaves to reduce risk of
insect and water damage.
Main Panel
·
Major Concern, Repair: The
main distribution panel is obsolete and should be replaced.
·
Repair: Circuits within the
main distribution panel that are doubled up (referred to as “double taps”)
should be separated. Each circuit should be served by a separate fuse or
breaker.
Distribution Wiring
·
Repair: All junction boxes
should be fitted with cover plates, in order to protect the wire connections. One in the attic on the east ceiling rafter is
not covered.
Outlets
·
Repair: Ungrounded 3-prong
outlets (all except upstairs hallway bathroom) should be repaired. In some
cases a ground wire may be present in the electrical box and simply needs to be
connected. If no ground is present “repair” can be as simple as filling the
ground slot with epoxy. Better, since having a ground increases safety, a
grounded circuit could be strung to this outlet, or a separate ground wire
could be connected. Some electrical codes allow the installation of a ground
fault circuit interrupter (GFCI) type outlet where grounding is not provided.
In this case the GFCI may work but can’t be tested by normal means.
·
Recommend: The installation
of a ground fault circuit interrupter (GFCI) is recommended at all locations
within 6 feet of a water source; kitchen counter, bathroom sink; exterior,
etc. A GFCI offers increased protection
from shock or electrocution.
·
Repair: Missing outlet cover
plate for the refrigerator should be replaced to avoid a shock hazard.
Lights
·
Repair: The exterior garage light
is inoperative. If the bulbs are not blown, the circuit should be repaired.
Furnace
·
Repair: The electronic air
cleaner did not appear to the functioning at the time of inspection.
House Fan
·
Repair: The house fan is
inoperative. Improvement is discretionary.
Supply Plumbing
·
Monitor: The old steel
piping is subject to corrosion on the interior of the pipe. As corrosion builds
up, the inside diameter of the pipe becomes constricted, resulting in a loss of
water pressure. This piping is typically replaced when the loss of pressure can
no longer be tolerated.
Plumbing Fixtures
·
Repair: The kitchen faucet
is leaking to the cabinet floor below.
·
Repair: The bathroom sink
drain plugs are missing, inoperative or damaged and needs repair.
·
Monitor, Repair: The master
bathroom bathtub drain plug is missing. Repair is discretionary.
·
Monitor, Repair: The hallway
bathroom bathtub drain plug is inoperative. Repair is discretionary.
·
Monitor, Repair: The basement
sink under the stairway has only working faucet. The pipe has been disconnected on the other
side.
Fireplaces
·
Repair: The fireplace
chimney should be inspected and cleaned prior to operation.
·
Monitor, Repair: The
fireplace damper only slightly opens. Repairs
may be needed.
·
Monitor, Repair: The basement
fireplace vent is blocked off with paper.
  THE SCOPE OF THE INSPECTION
All components designated for inspection in the ASHIâ Standards of Practice are inspected, except as may be
noted in the “Limitations of Inspection” sections within this report.
It is the goal of the inspection to put a home buyer in a
better position to make a buying decision.
Not all improvements will be identified during this inspection. Unexpected repairs should still be
anticipated. The inspection should not
be considered a guarantee or warranty of any kind.
Please refer to the pre-inspection
contract for a full explanation of the scope of the inspection.
WEATHER
CONDITIONS
Dry weather conditions prevailed at the time of the
inspection.
The estimated outside temperature was 30 degrees F.
RECENT
WEATHER CONDITIONS
Weather conditions leading up to the inspection have been
relatively dry.
  description of Structure
Foundation: ·Stone ·Basement
Configuration ·50% Of Foundation Was Not
Visible
Columns: ·Not Visible Due To
Finished Walls and Storage
Floor Structure: ·Wood
Joist
Wall Structure: ·Wood
Frame
Ceiling Structure: ·Joist
Roof Structure: ·Rafters ·Spaced
Plank Sheathing
  Structure observations
Positive Attributes
The construction of the home is good quality. The materials
and workmanship, where visible, are good.
The visible joist spans appear to be within typical construction
practices. The inspection did not
discover evidence of substantial structural movement.
General Comments
No major defects were observed in the accessible structural
components of the house.
recommendations / observations
Foundation
·
Monitor: Common minor
settlement cracks were observed in the foundation walls. This implies that some
structural movement of the building has occurred. Cracks of this type should be
watched for any sign of additional movement. In the absence of any sign of
ongoing movement, repair should not be necessary.
·
Monitor: The basement floor
slab has typical cracks for a house of this age. Cracks are very common and are not normally a
concern. Small portions of the floor
have been removed and should be filled.
Floors
·
Monitor: Minor unevenness
was observed in the floor structure. This condition is common. It may be the
result of the materials, framing design, installation methods and aging of the
building. There was not evidence of need for immediate, costly repair.
·
Monitor, Repair: Minor
unevenness was observed in the floor structure. This condition is common. It
may be the result of the materials, framing design, installation methods and
aging of the building. There was not evidence of need for immediate, costly
repair.
·
Reecommend: Parging
of the interior of the old foundation walls is desirable to improve appearance
and avoid further foundation damage.
  limitations of Structure
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Structural components concealed
behind finished surfaces could not be inspected.
·
Only a
representative sampling of visible structural components were inspected.
·
Furniture and/or storage
restricted access to some structural components.
·
Engineering or architectural
services such as calculation of structural capacities, adequacy, or integrity
are not part of a home inspection.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Roofing
Roof Covering: ·Asphalt
Shingle
Roof Flashings: ·Metal
Chimneys: ·Masonry
Roof Drainage System: ·Galvanized Steel ·Downspouts
discharge below grade
Skylights: ·None
Method of Inspection: ·Viewed with
binoculars
  Roofing observations
Positive Attributes
The roof coverings are to be in generally good
condition. The installation of the
roofing materials has been performed in a professional manner. The quality of
the installation is above average. Better than average quality materials have
been employed as roof coverings. The
steep pitch of the roof should result in a longer than normal life expectancy
for roof coverings. Roof flashing
details appear to be in good order. In
all, the roof coverings show evidence of normal wear and tear for a home of
this age.
recommendations / observations
Chimneys
·
Repair: The masonry chimney
needs re-pointing (replacing the mortar between the bricks) to avoid water
damage.
·
Recommend: A rain cap should
be installed on the masonry chimney and the chimney flue should be checked for
damage. Damaged flues can be unsafe.
Gutters & Downspouts
·
Repair: The downspout(s)
should discharge water at least five (5) feet from the house. Storm water
should be encouraged to flow away from the building at the point of
discharge. One on the west side does not
have an extension on it to direct water away from the building.
  limitations of Roofing
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Not all of the
underside of the roof sheathing is inspected for evidence of leaks.
·
Evidence of prior leaks may be
disguised by interior finishes.
·
Estimates of remaining roof life
are approximations only and do not preclude the possibility of leakage. Leakage
can develop at any time and may depend on rain intensity, wind direction, ice
build up, and other factors.
·
Antennae, chimney/flue interiors
which are not readily accessible are not inspected and could require repair.
·
Roof inspection may be limited by
access, condition, weather, or other safety concerns.
·
Portions of the roof were viewed
from the ground using binoculars. Some
sections of the roof could not be viewed.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Exterior
Wall Covering: ·Stucco
Eaves, Soffits, And
Fascias: ·Wood
Exterior Doors: ·Solid
Wood
Window/Door Frames and Trim: ·Wood
Entry Driveways: ·Concrete
Entry Walkways And Patios:
·Concrete
Porches, Decks, Steps, Railings: ·Concrete
Overhead Garage Door(s): ·Steel
·Automatic
Opener Installed
Surface Drainage: ·Level Grade
Retaining Walls: ·None
Fencing: ·Wood
Positive Attributes
The wood window frames are in generally good condition. There is no significant wood/soil contact
around the perimeter of the house, thereby reducing the risk of insect
infestation or rot. The driveway and
walkways are in good condition.
General Comments
The exterior of the home is generally in good condition. The exterior of the home shows normal wear
and tear for a home of this age.
recommendations / observations
Exterior Walls
·
Monitor: Common minor cracks were observed on the
exterior wall on the west side. This implies that structural movement has
occurred. The location, size, shape of these cracks is common. The inspection
did not find evidence of significant movement requiring immediate major
repairs.
·
Monitor, Repair: Localized
damage at the base of the stucco exterior walls of the garage should be
repaired.
Garage
·
Repair, Safety Issue: The garage door opener did not
automatically reverse under resistance to closing. There is a serious risk of
injury, particularly to children, under this condition. The opener may need replacement.
·
Monitor, Safety Issue: Pronounced
floor cracks were noted in the garage. While this amount of cracking is
unusual, this slab is not a structural component you should be aware of the
trip hazard.
Driveway
·
Monitor: The driveway has
settled and cracked. Persisting movement
may result in the need for repairs.
Walkway
·
Recommend, Safety Issue: The
walkway presents a trip hazard. This condition should be altered for improved
safety.
Landscaping
·
Repair: Tree branches should
be kept trimmed away from the house to avoid damage to the building.
·
Repair: Shrubs/bushes
growing near exterior walls and vines growing on the exterior walls should be
kept trimmed away from siding, window trims, and the eaves to reduce risk of
insect and water damage.
  limitations of Exterior
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
A representative sample of
exterior components was inspected rather than every occurrence of components.
·
The inspection does not include an
assessment of geological, geotechnical, or hydrological conditions, or
environmental hazards.
·
Screening, shutters, awnings, or
similar seasonal accessories, fences, recreational facilities, outbuildings,
seawalls, break-walls, docks, erosion control and earth stabilization measures
are not inspected unless specifically agreed-upon and documented in this
report.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Electrical
Size of Electrical Service: ·120/240 Volt Main Service
- Service Size: 200 Amp
Service Drop: ·Overhead
Service Entrance Conductors: ·Aluminum
Service Equipment &
Main
Disconnects: ·Main
Service Rating 60 Amps
·Fuses ·Located: Basement
Service Grounding: ·Ground Connection Not
Visible
Service Panel &
Overcurrent Protection: ·Panel
Rating: 60 Amp ·Fuses ·Located: Basement
Sub-Panel(s): ·Panel
Rating: 30 Amp ·Fuses
Distribution Wiring: ·Copper
Wiring Method: ·
Non-Metallic Cable "Romex" ·Fabric-Covered ·Knob-and-Tube Copper
Switches & Receptacles: ·Grounded
and Ungrounded
Ground Fault Circuit Interrupters: ·None Found
  Electrical observations
Positive Attributes
The electrical panel is well arranged and all fuses/breakers
are properly sized. Generally speaking,
the electrical system is in good order.
All outlets and light fixtures that were tested operated
satisfactorily. The distribution of
electricity within the home is good.
Dedicated 220 volt circuits have been provided for all 220 volt
appliances within the home. All visible
wiring within the home is copper. This is a good quality electrical
conductor.
General Comments
Major Concern:
The electrical system is an aging system. In addition to engaging a licensed
electrician to repair the items listed below, it is recommended that all
electrical components and connections be further investigated. Additional
defects may be concealed from view. Unsafe electrical conditions represent a
shock hazard. Substantial updating may be required.
recommendations / observations
Main Panel
·
Major Concern, Repair: The
main distribution panel is obsolete and should be replaced.
·
Repair: Circuits within the
main distribution panel that are doubled up (referred to as “double taps”)
should be separated. Each circuit should be served by a separate fuse or
breaker.
Distribution Wiring
·
Repair: All junction boxes
should be fitted with cover plates, in order to protect the wire connections. One in the attic on the east ceiling rafter is
not covered.
Outlets
·
Repair: Ungrounded 3-prong
outlets (all except upstairs hallway bathroom) should be repaired. In some
cases a ground wire may be present in the electrical box and simply needs to be
connected. If no ground is present “repair” can be as simple as filling the
ground slot with epoxy. Better, since having a ground increases safety, a
grounded circuit could be strung to this outlet, or a separate ground wire
could be connected. Some electrical codes allow the installation of a ground
fault circuit interrupter (GFCI) type outlet where grounding is not provided.
In this case the GFCI may work but can’t be tested by normal means.
·
Recommend: The installation
of a ground fault circuit interrupter (GFCI) is recommended at all locations
within 6 feet of a water source; kitchen counter, bathroom sink; exterior,
etc. A GFCI offers increased protection
from shock or electrocution.
·
Repair: Missing outlet cover
plate for the refrigerator should be replaced to avoid a shock hazard.
Lights
·
Repair: The exterior garage light
is inoperative. If the bulbs are not blown, the circuit should be repaired.
Discretionary Improvements
The size of the electrical service
supplied to the home may not be
sufficient, depending on the lifestyle of the occupants. A marginally sized electrical service is not a safety concern, but
may represent and inconvenience if the main fuses (or breakers) blow, shutting
down the power in all or part of the home. If it is found that the main fuses
(or breakers) blow regularly, a larger electrical service may be desirable. If
care is taken not to run major electrical appliances simultaneously, it is
unlikely that the service will overload. The use of gas fired kitchen appliances
will also reduce the load on the electrical service.
The installation of ground fault
circuit interrupter (GFCI) devices is advisable on exterior, garage, bathroom
and some kitchen outlets. Any whirlpool or swimming pool equipment should also
be fitted with GFCI’s as they offer protection from
shock or electrocution.
During the course of any renovating,
it is recommended that old wiring be replaced.
Grounded outlets may be desirable in
some areas where ungrounded outlets exist. This will depend on electrical
needs.
  limitations of Electrical
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Electrical components concealed
behind finished surfaces are not inspected.
·
Only a representative sampling of
outlets and light fixtures were tested.
·
Furniture and/or storage
restricted access to some electrical components which may not be inspected.
·
The inspection does not include
remote control devices, alarm systems and components, low voltage wiring,
systems, and components, ancillary wiring, systems, and other components which
are not part of the primary electrical power distribution system.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Heating
Energy Source: ·Gas
Heating System Type: ·Forced Air Furnace ·Manufacturer:
Lennox ·Serial
Number: 2801A53677
Vents, Flues, Chimneys: ·Masonry-Lined
Heat Distribution Methods: ·Ductwork
Other Components: An electronic air cleaner has
been installed on this forced air system. This feature provides better air
cleaning than conventional filters.
  Heating observations
Positive Attributes
The heating system is in generally good condition. Adequate heating capacity is provided by the
system. Heat distribution within the home
is adequate. An electronic air cleaner
has been installed on this forced air system. This feature provides better air
cleaning than conventional filters.
General Comments
The heating system shows no visible evidence of major
defects. No repairs to the heating
system are necessary at this time.
recommendations / observations
Furnace
·
Repair: The electronic air
cleaner did not appear to the functioning at the time of inspection.
  limitations of Heating
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
The adequacy of heat supply or
distribution balance is not inspected.
·
The interior of flues or chimneys
which are not readily accessible are not inspected.
·
The furnace heat exchanger,
humidifier, or dehumidifier, and electronic air filters are not inspected.
·
Solar space heating
equipment/systems are not inspected.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Cooling
/ Heat Pumps
Energy Source: ·Electricity
Central System Type: ·Air Cooled Central Air Conditioning ·Manufacturer:
Lennox ·Serial
Number: 5803C31127
Through-Wall Equipment: ·Not Present
Other Components: ·House Fan
  Cooling / Heat Pumps observations
Positive Attributes
The capacity and configuration of the system should be
sufficient for the home. The location of
the return air vents is well suited to air conditioning.
recommendations / observations
House Fan
·
Repair: The house fan is
inoperative. Improvement is discretionary.
  limitations of Cooling /
Heat Pumps inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Window mounted air conditioning
units are not inspected.
·
The cooling supply adequacy or
distribution balance are not inspected.
·
The air conditioning system could
not be tested as the outdoor temperature was below 60 degrees F.
Please also refer to the pre-inspection contract
for a detailed explanation of the scope of this inspection.
  description of Insulation
/ Ventilation
Attic Insulation: ·Rolled Fiberglass in Main
Attic
Exterior Wall Insulation: ·Not Visible
Basement Wall Insulation: ·None Visible
Vapor Retarders: ·Kraft
Paper
Roof Ventilation: ·Roof Vents ·Gable Vents
Exhaust Fan/vent Locations: ·Dryer
  Insulation / Ventilation observations
Positive Attributes
Insulation levels are typical for a home of this age and
construction.
General Comments
Upgrading insulation levels in a home is an improvement
rather than a necessary repair.
recommendations / Energy saving Suggestions
  limitations of Insulation /
Ventilation inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Insulation/ventilation type and
levels in concealed areas are not inspected. Insulation and vapor barriers are
not disturbed and no destructive tests (such as cutting openings in walls to
look for insulation) are performed.
·
Potentially hazardous materials
such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI) cannot be
positively identified without a detailed inspection and laboratory
analysis. This is beyond the scope of
the inspection.
·
An analysis of indoor air quality
is not part of our inspection unless explicitly contracted-for and discussed in
this or a separate report.
·
Any estimates of insulation R
values or depths are rough average values.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Plumbing
Water Supply Source: ·Public Water Supply
Service Pipe to House: ·Steel
Main Water Valve Location: ·Front Wall of
Basement
Interior Supply Piping: ·Steel
Waste System: ·Public
Sewer System
Drain, Waste, & Vent Piping: ·Cast Iron
Water Heater: ·Gas ·Approximate
Capacity (in gallons): 50 ·Manufacturer:
Richmond ·Serial Number: 0704402612
Fuel Shut-Off Valves: ·Natural Gas Main Valve At Meter
  Plumbing observations
Positive Attributes
The plumbing system is in generally good condition. The water pressure supplied to the fixtures
is reasonably good. A typical drop in flow was experienced when two fixtures
were operated simultaneously. The
plumbing fixtures appear to have been well-maintained. The water heater is a relatively new unit. As
the typical life expectancy of water heaters is 7 to 12 years, this unit should
have several years of remaining life.
recommendations / observations
Supply Plumbing
·
Monitor: The old steel
piping is subject to corrosion on the interior of the pipe. As corrosion builds
up, the inside diameter of the pipe becomes constricted, resulting in a loss of
water pressure. This piping is typically replaced when the loss of pressure can
no longer be tolerated.
Plumbing Fixtures
·
Repair: The kitchen faucet
is leaking to the cabinet floor below.
·
Repair: The bathroom sink
drain plugs are missing, inoperative or damaged and needs repair.
·
Monitor, Repair: The master
bathroom bathtub drain plug is missing. Repair is discretionary.
·
Monitor, Repair: The hallway
bathroom bathtub drain plug is inoperative. Repair is discretionary.
·
Monitor, Repair: The basement
sink under the stairway has only working faucet. The pipe has been disconnected on the other
side.
  limitations of Plumbing
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions:
·
Portions of the plumbing system
concealed by finishes and/or storage (below sinks, etc.), below the structure,
or beneath the ground surface are not inspected.
·
Water quantity and water quality
are not tested unless explicitly contracted-for and discussed in this or a
separate report.
·
Clothes washing machine
connections are not inspected.
·
Interiors of flues or chimneys
which are not readily accessible are not inspected.
·
Water conditioning systems, solar
water heaters, fire and lawn sprinkler systems, and private waste disposal
systems are not inspected unless explicitly contracted-for and discussed in
this or a separate report.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Interior
Wall And Ceiling Materials:
·Plaster
Floor Surfaces: ·Carpet ·Tile ·Wood
Window Type(s) & Glazing: ·Double/Single Hung ·Single
Pane with Storm Window
Doors: ·Wood-Hollow
Core ·French
Doors ·Storm Door(s)
  Interior observations
General Condition of Interior
Finishes
On the whole, the interior finishes of the home are in above
average condition. Typical minor flaws were observed in some areas. As is the case in many old homes, the plaster
finishes show signs of weakening. Over time, the plaster begins to bulge as it
looses its bond to the wall. While this poses no short term concern, it may
become necessary to substantially improve or replace sections of plaster,
particularly during redecorating. Where wallpaper is employed, the wallpaper
often serves to hold the old plaster in place. When stripping wallpaper, the
plaster sometimes weakens as the wallpaper is removed. This explains why many
people wallpaper or paint over existing wallpaper. It should be noted that
special fabrics exist that can be applied over weakened plaster, much like
wallpaper, to reinforce the plaster prior to painting or wallpapering. This is
far more cost effective than replacing plaster.
General Condition of Windows
and Doors
The majority of the doors and windows are average
quality. The windows have, for the most
part, been well-maintained.
General Condition of Floors
The floors of the home are relatively level and walls are
relatively plumb.
recommendations / observations
Wall / Ceiling Finishes
·
Monitor: Damage to the basement
interior finish was observed.
·
Monitor: Typical drywall/plaster
flaws were observed that could include minor cracks, loose tape, cracked or
bulging plaster, peeling paper, minor patching, etc. Any repairs would be discretionary.
·
Monitor: Loose or weakened
finishes were detected.
Floors
·
Monitor, Repair: The tile
floor is loose and/or cracked in the basement and side porch. Repair is discretionary.
Windows
·
Monitor: Some windows are
painted/stuck shut. Improvement can be undertaken as desired.
·
Monitor: Two or three storm
windows are cracked. Improvement is not a high priority.
·
Monitor, Repair: Window locking
hardware is loose, missing or damaged on a few windows. Repairs are discretionary.
Doors
·
Monitor, Repair: Several
doors should be trimmed or adjusted as necessary to work properly.
·
Monitor, Repair: Door to the
half bath should be adjusted as necessary to lock properly.
·
Monitor, Repair: The master bedroom
pocket door needs adjustment to slide properly.
Basement Leakage
·
Monitor: No evidence of
moisture penetration was visible in the basement at the time of the inspection.
It
should be understood that it is impossible to predict whether moisture
penetration will pose a problem in the future. The vast majority of
basement leakage problems are the result of insufficient control of storm water
at the surface. The ground around the house should be sloped to encourage water
to flow away from the foundation. Gutters and downspouts should act to collect
roof water and drain the water at least five (5) feet from the foundation or
into a functional storm sewer. Downspouts that are clogged or broken below
grade level, or that discharge too close to the foundation are the most common
source of basement leakage. Please refer to the Roofing and Exterior sections
of the report for more information.
In the event that basement leakage problems are experienced, lot and roof
drainage improvements should be undertaken as a first step. Please beware of
contractors who recommend expensive solutions. Excavation, damp-proofing and/or
the installation of drainage tiles should be a last resort. In some cases,
however, it is necessary. Your plans for using the basement may also influence
the approach taken to curing any dampness that is experienced.
Discretionary Improvements
Install new exterior lock sets upon
taking possession of the home.
  limitations of Interior
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions
·
Furniture, storage, appliances
and/or wall hangings are not moved to permit inspection and may block defects.
·
Carpeting, window treatments,
central vacuum systems, household appliances, recreational facilities, paint,
wallpaper, and other finish treatments are not inspected.
·
The adequacy of the fireplace draw
cannot be determined during a visual inspection.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Appliances
Appliances Tested: ·Electric
Range ·Microwave
Oven ·Dishwasher ·Waste Disposer ·Refrigerator
Laundry Facility: ·Dryer Vented to Building Exterior ·Hot
and Cold Water Supply for Washer ·Waste
Standpipe for Washer
Other Components Tested: ·Door Bell
  Appliances observations
Positive Attributes
The appliances are to be in generally good condition. All appliances that were tested responded
satisfactorily. The kitchen and laundry
facilities are well organized. The
kitchen cabinetry is above average quality.
recommendations / observations
  limitations of Appliances
inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions
·
Thermostats, timers and other
specialized features and controls are not tested.
·
The temperature calibration,
functionality of timers, effectiveness, efficiency and overall performance of
appliances is outside the scope of this inspection.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.
  description of Fireplaces
/ Wood Stoves
Fireplaces: ·Masonry
Firebox
Vents, Flues, Chimneys: ·Masonry Chimney-Lined
  Fireplaces / Wood Stoves observations
General Comments
On the whole, the fireplace and its components were found to
be in average condition. Typical flaws were observed in some areas.
recommendations / observations
Fireplaces
·
Repair: The fireplace
chimney should be inspected and cleaned prior to operation.
·
Monitor, Repair: The
fireplace damper only slightly opens. Repairs
may be needed.
·
Monitor, Repair: The basement
fireplace vent is blocked off with paper.
  limitations of Fireplaces /
Wood Stoves inspection
As we have discussed and as described in your inspection
contract, this is a visual inspection limited in scope by (but not restricted
to) the following conditions
·
The interiors of flues or chimneys
are not inspected.
·
Firescreens,
fireplace doors, appliance gaskets and seals, automatic fuel feed devices,
mantles and fireplace surrounds, combustion make-up air devices, and heat
distribution assists (gravity or fan-assisted) are not inspected.
·
The inspection does not involve
igniting or extinguishing fires nor the determination of draft.
·
Fireplace inserts, stoves, or
firebox contents are not moved.
·
The adequacy of the fireplace draw
is not determined during a visual inspection; for safety reasons, if no fire is
burning we do not ignite fires nor light paper or other materials.
Please also refer to the pre-inspection
contract for a detailed explanation of the scope of this inspection.