Report Overview
THE HOUSE IN PERSPECTIVE
This is a well built home. As with all homes, ongoing
maintenance is required and improvements to the systems of the home will
be needed over time. The improvements that are
recommended in this report are not considered unusual for a home of this
age and location.
Please remember that there is no such thing as a perfect
home.
CONVENTIONS USED IN THIS
REPORT
For your convenience, the following conventions have
been used in this report.
Major Concern: a system or
component which is considered significantly deficient or is unsafe.
Significant deficiencies need to be corrected and, except for some
safety items, are likely to involve significant expense.
Safety Issue: denotes a condition that is
unsafe and in need of prompt attention.
Repair: denotes a system or
component which is missing or which needs corrective action to assure
proper and reliable function.
Improve: denotes improvements which are
recommended but not required.
Monitor: denotes a system or component
needing further investigation and/or monitoring in order to determine
if
repairs are necessary.
Please note that those observations listed under
“Discretionary Improvements” are not essential repairs, but represent
logical long term improvements.
·
For the purpose of this
report, it is assumed that the house faces north.
IMPROVEMENT RECOMMENDATION
HIGHLIGHTS / summary
The following is a synopsis of the potentially
significant improvements that should be budgeted for over the short
term. Other significant
improvements, outside the scope of this inspection, may also be
necessary. Please refer to
the body of this report for further details on these and other
recommendations.
All issues
found in this report should be addressed with the appropriate parties to
make any improvements, corrections or repairs necessary. All improvements, corrections
and repairs should meet the satisfaction of the client named on this
report and the inspection agreement associated with this report prior to
closing. This report and
the findings listed herein are intended for the client only and is not transferable without a signed written
agreement.
Foundation
·
Monitor: Common minor settlement
cracks were observed in the foundation walls. This implies that some
structural movement of the building has occurred. Cracks of this type
should be watched for any sign of additional movement. In the absence of
any sign of ongoing movement, repair should not be necessary.
·
Monitor: The basement floor slab has
typical cracks usually the result of shrinkage and/or settling of the
slab as it cures. Shrinkage cracks are very common and are not normally
a concern.
Sloped Roofing
·
Monitor: The life expectancy of wood
roofs is generally 15 t0 20 years in this area. This will depend on
several factors such as the quality of shingle or shake, the slope of
the roof (steeper is better), the amount of exposed shingle, and the
amount of sun or shade. As with all roofs, annual maintenance is needed.
Cracked, curled, or displaced shingles or shakes should be repaired. As
a rule of thumb, replacement of the entire roof covering may be logical
if more than ten percent of the wood roof requires repair.
Gutters &
Downspouts
·
Repair: The downspout(s) should
discharge water at least five (5) feet from the house. Storm water
should be encouraged to flow away from the building at the point of
discharge.
Exterior Walls
·
Repair: Localized rot/damage was
observed in the siding. Following repair of the damaged areas (which
should be combined with exterior painting/maintenance) proper
maintenance of the siding and control of water from roof or surface
runoff can avoid further damage.REPAIRED
·
Repair: Localized rot was observed
in the trim around siding/doors. Following repair of the damaged areas
(which should be combined with exterior painting/maintenance) proper
maintenance of the siding and control of water from roof or surface
runoff can avoid further damage.REPAIRED
Garage
·
Repair, Safety Issue: No safety springs/cables
were noted on the garage door springs. The installation of the
springs/cables would improve safety during operation.
·
Monitor: The garage floor slab has
typical cracks usually the result of shrinkage and/or settling of the
slab.
Lot Drainage
·
Recommend: The grading should be
improved to promote the flow of storm water away from the house. This
can often be accomplished by the addition of top soil. The ground should
slope away from the house at a rate of one inch per foot for at least
the first ten feet. At least eight (8) inches of clearance should be
maintained between soil level and the bottom of exterior wall siding.
Patio
·
Monitor: The patio has settled and
cracked. Persisting
movement may result in the need for repairs.
Landscaping
·
Monitor/Repair: Shrubs/bushes growing near
exterior walls and vines growing on the exterior walls should be kept
trimmed away from siding, window trims, and the eaves to reduce risk of
insect and water damage.
Outlets
·
Repair: A ground fault circuit
interrupter (GFCI) outlet at the electrical panel did not respond
correctly to testing during the inspection. This receptacle should be
replaced.
Lights
·
Repair: There are lights that are
inoperative. If the bulbs are not blown, the circuit should be
repaired.
Supply Air
Ductwork
·
Monitor: The east closet supply seems
disconnected as there is little/no air flow. Supplemental heat in the form of
an electric baseboard heater has been installed in the east closet to
alleviate any cold/heat issues.
Central Air
Conditioning
·
Repair: Damaged insulation on
refrigerant lines should be repaired.
·
Improve: The outdoor unit of the air
conditioning system requires cleaning.
·
Monitor: Evidence of prior leakage
was observed at the condensate tray of the air conditioning
system.
Water Heater
·
Monitor: Water heaters have a typical
life expectancy of 7 to 12 years. The existing unit is approaching or
has exceeded this age range. One cannot predict with certainty when
replacement will become necessary
Fixtures
·
Repair: The faucet in the upstairs
shared bathroom, left side is leaking.
·
Improve: Cracked, deteriorated and/or
missing bathtub enclosure grout and caulk should be improved.
Wall / Ceiling
Finishes
·
Monitor: Evidence of patching was
detected.
·
Monitor: Damage to the interior
finish was observed.
·
Monitor: Minor cracks were
noted.
·
Monitor: Typical drywall flaws were
observed.
Floors
·
Monitor: The carpet is stained (wear
and tear).
Windows
·
Repair: The window in the kitchen
dining area is broken.
Doors
·
Repair: Door to the master bedroom
should be adjusted as necessary to latch properly.
Basement Leakage
·
Monitor: No evidence of moisture
penetration was visible in the basement at the time of the inspection.
It should be understood that it is
impossible to predict whether moisture penetration will pose a problem
in the future. The vast majority of basement leakage problems
are the result of insufficient control of storm water at the surface.
The ground around the house should be sloped to encourage water to flow
away from the foundation. Gutters and downspouts should act to collect
roof water and drain the water at least five (5) feet from the
foundation or into a functional storm sewer. Downspouts that are clogged
or broken below grade level, or that discharge too close to the
foundation are the most common source of basement leakage. Please refer
to the Roofing and Exterior sections of the report for more
information.
In the event that basement leakage problems are
experienced, lot and roof drainage improvements should be undertaken as
a first step. Please beware of contractors who recommend expensive
solutions. Excavation, damp-proofing and/or the installation of drainage
tiles should be a last resort. In some cases, however, it is necessary.
Your plans for using the basement may also influence the approach taken
to curing any dampness that is experienced.
Fireplaces
·
Monitor/Repair: The hearth outside the
fireplace is damaged (broken/cracked tile).
THE SCOPE OF THE INSPECTION
All components designated for inspection in the
ASHIâ
Standards of Practice are inspected, except as may be noted in the
“Limitations of Inspection” sections within this report.
It is the goal of the inspection to put a home buyer
in a better position to make a buying decision. Not all improvements will be
identified during this inspection.
Unexpected repairs should still be anticipated. The inspection should not be
considered a guarantee or warranty of any kind.
Please refer to the pre-inspection
contract for a full explanation of the scope of the inspection.
WEATHER
CONDITIONS
There was snow on the ground during the course of the
inspection.
The estimated outside temperature was 25 degrees F.
RECENT
WEATHER CONDITIONS
Winter weather conditions have been experienced in
the days leading up to the inspection.
description of Structure
Foundation:
·Poured
Concrete
·Basement
Configuration ·25%
Of Foundation Was Not Visible
Columns:
·Steel
Floor
Structure:
·Wood
Joist
Wall
Structure:
·Wood
Frame
Ceiling
Structure:
·Joist
Roof
Structure:
·Rafters
·Spaced
Plank Sheathing
Positive
Attributes
The construction of the home is good quality. The
materials and workmanship, where visible, are good. The visible joist spans appear
to be within typical construction practices. The inspection did not discover
evidence of substantial structural movement.
recommendations / observations
Foundation
·
Monitor: Common minor settlement
cracks were observed in the foundation walls. This implies that some
structural movement of the building has occurred. Cracks of this type
should be watched for any sign of additional movement. In the absence of
any sign of ongoing movement, repair should not be necessary.
·
Monitor: The basement floor slab has
typical cracks usually the result of shrinkage and/or settling of the
slab as it cures. Shrinkage cracks are very common and are not normally
a concern.
limitations of Structure
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Structural components
concealed behind finished surfaces could not be inspected.
·
Only a
representative sampling of visible structural components were
inspected.
·
Furniture and/or storage
restricted access to some structural components.
·
Engineering or
architectural services such as calculation of structural capacities,
adequacy, or integrity are not part of a home inspection.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Roofing
Roof
Covering:
·Wood
Shingle
Roof
Flashings:
·Metal
Chimneys:
·Metal
below siding
Roof
Drainage System:
·Aluminum
·Downspouts
discharge above grade
Method
of Inspection:
·Viewed
from ladder at eave ·Viewed
with binoculars ·Viewed
from window
Positive
Attributes
The roof coverings are to be in generally good
condition. The steep pitch
of the roof should result in a longer than normal life expectancy for
roof coverings.
recommendations / observations
Sloped Roofing
·
Monitor: The life expectancy of wood
roofs is generally 15 t0 20 years in this area. This will depend on
several factors such as the quality of shingle or shake, the slope of
the roof (steeper is better), the amount of exposed shingle, and the
amount of sun or shade. As with all roofs, annual maintenance is needed.
Cracked, curled, or displaced shingles or shakes should be repaired. As
a rule of thumb, replacement of the entire roof covering may be logical
if more than ten percent of the wood roof requires repair.
Gutters &
Downspouts
·
Repair: The downspout(s) should
discharge water at least five (5) feet from the house. Storm water
should be encouraged to flow away from the building at the point of
discharge.
limitations of Roofing
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Not all
of the underside of the roof sheathing is inspected for evidence
of leaks.
·
Evidence of prior leaks may
be disguised by interior finishes.
·
Estimates of remaining roof
life are approximations only and do not preclude the possibility of
leakage. Leakage can develop at any time and may depend on rain
intensity, wind direction, ice build up, and other factors.
·
Antennae, chimney/flue
interiors which are not readily accessible are not inspected and could
require repair.
·
Roof inspection may be
limited by access, condition, weather, or other safety
concerns.
·
Portions of the roof were
viewed from the ground using binoculars. Some sections of the roof could
not be viewed.
·
Portions of the roof were
viewed from a ladder at the edge of the roof. Some sections of the roof were
not in view.
·
Snow on the roof restricted
the inspection.
·
Unfavorable weather
restricted the inspection of the roofing system.
·
Some sections of the
roofing surface were concealed from view.
·
A chimney was not entirely
visible during the inspection of the roofing system.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Exterior
Wall
Covering:
·Stucco
·Wood
Siding
Eaves,
Soffits, And
Fascias:
·Wood
Exterior
Doors:
·Metal
Window/Door
Frames and Trim:
·Wood
Entry
Driveways:
·Concrete
·Not
visible due to snow
Entry
Walkways And Patios:
·Concrete
·Not
visible due to snow
Porches,
Decks, Steps, Railings:
·Concrete
Overhead
Garage Door(s):
·Wood
·Automatic
Opener Installed
Surface
Drainage:
·Level
Grade
Retaining
Walls:
·Wood
·Block
Fencing:
·Wood
Positive
Attributes
There is no significant wood/soil contact around the
perimeter of the house, thereby reducing the risk of insect infestation
or rot. The auto reverse
mechanism on the overhead garage door responded properly to testing.
This safety feature should be tested regularly as a door that doesn’t
reverse can injure someone or fall from the ceiling. Refer to the
owner’s manual or contact the manufacturer for more information. The garage appears to be fully
insulated. The garage
completely finished. Freeze
resistant hose bibs (exterior faucets) have been installed.
recommendations / observations
Exterior Walls
·
Repair: Localized rot/damage was
observed in the siding. Following repair of the damaged areas (which
should be combined with exterior painting/maintenance) proper
maintenance of the siding and control of water from roof or surface
runoff can avoid further damage.REPAIRED
·
Repair: Localized rot was observed
in the trim around siding/doors. Following repair of the damaged areas
(which should be combined with exterior painting/maintenance) proper
maintenance of the siding and control of water from roof or surface
runoff can avoid further damage.REPAIRED
Garage
·
Repair, Safety Issue: No safety springs/cables
were noted on the garage door springs. The installation of the
springs/cables would improve safety during operation.
·
Monitor: The garage floor slab has
typical cracks usually the result of shrinkage and/or settling of the
slab.
Lot Drainage
·
Recommend: The grading should be
improved to promote the flow of storm water away from the house. This
can often be accomplished by the addition of top soil. The ground should
slope away from the house at a rate of one inch per foot for at least
the first ten feet. At least eight (8) inches of clearance should be
maintained between soil level and the bottom of exterior wall siding.
Patio
·
Monitor: The patio has settled and
cracked. Persisting
movement may result in the need for repairs.
Landscaping
·
Monitor/Repair: Shrubs/bushes growing near
exterior walls and vines growing on the exterior walls should be kept
trimmed away from siding, window trims, and the eaves to reduce risk of
insect and water damage.
limitations of Exterior
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
A representative sample of
exterior components was inspected rather than every occurrence of
components.
·
The inspection does not
include an assessment of geological, geotechnical, or hydrological
conditions, or environmental hazards.
·
Screening, shutters,
awnings, or similar seasonal accessories, fences, recreational
facilities, outbuildings, seawalls, break-walls, docks, erosion control
and earth stabilization measures are not inspected unless specifically
agreed-upon and documented in this report.
·
Storage in the garage
restricted the inspection.
·
Snow restricted an
inspection of the lot and various other aspects of the exterior of the
house.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Electrical
Size
of Electrical Service:
·120/240
Volt Main Service - Service Size: 200 Amp
Service
Drop:
·Underground
Service
Entrance Conductors:
·Aluminum
Service
Equipment &
Main
Disconnects:
·Main
Service Rating 200 Amps ·Breakers ·Located:
East wall of basement
Service
Grounding:
·Copper
·Water
Pipe Connection
Service
Panel &
Distribution
Wiring:
·Copper
Wiring
Method:
·
Non-Metallic Cable "Romex"
Switches
& Receptacles:
·Grounded
Ground
Fault Circuit Interrupters:
·Bathroom(s) ·Whirlpool ·Exterior ·Garage ·Kitchen ·Basement ·Electrical
Panel
Smoke
Detectors:
·Present
Positive
Attributes
The size of the electrical service is sufficient for
typical single family needs.
The electrical panel is well arranged and all fuses/breakers are
properly sized. Generally
speaking, the electrical system is in good order. The distribution of electricity
within the home is good.
All 3-prong outlets that were tested were appropriately
grounded. Dedicated 220
volt circuits have been provided for all 220 volt appliances within the
home. All visible wiring
within the home is copper. This is a good quality electrical
conductor.
recommendations / observations
Outlets
·
Repair: A ground fault circuit
interrupter (GFCI) outlet at the electrical panel did not respond
correctly to testing during the inspection. This receptacle should be
replaced.
Lights
·
Repair: There are lights that are
inoperative. If the bulbs are not blown, the circuit should be
repaired.
limitations of Electrical
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Electrical components
concealed behind finished surfaces are not inspected.
·
Only a representative
sampling of outlets and light fixtures were tested.
·
Furniture and/or storage
restricted access to some electrical components which may not be
inspected.
·
The inspection does not
include remote control devices, alarm systems and components, low
voltage wiring, systems, and components, ancillary wiring, systems, and
other components which are not part of the primary electrical power
distribution system.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Heating
Energy
Source:
·Gas
Heating
System Type:
·Forced
Air Furnace
·Electric
Heaters/Baseboards ·Manufacturer:
Resco
·Serial
Number: 4493A10778
Vents,
Flues, Chimneys:
·Metal-Single
Wall
Heat
Distribution Methods:
·Ductwork
Other
Components:
·Humidifier
Positive
Attributes
The heating system is in generally good
condition. Heating a home
with this type of heating system should be relatively economical. Adequate heating capacity is
provided by the system.
recommendations / observations
Supply Air
Ductwork
·
Monitor: The east closet supply seems
disconnected as there is little/no air flow. Supplemental heat in the form of
an electric baseboard heater has been installed in the east closet to
alleviate any cold/heat issues.
limitations of Heating
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
The adequacy of heat supply
or distribution balance is not inspected.
·
The interior of flues or
chimneys which are not readily accessible are not inspected.
·
The furnace heat exchanger,
humidifier, or dehumidifier, and electronic air filters are not
inspected.
·
Solar space heating
equipment/systems are not inspected.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Cooling / Heat
Pumps
Energy
Source:
·Electricity
Central
System Type:
·Air
Cooled Central Air Conditioning ·Manufacturer:
Resco
·Serial
Number: 4993E02819
Cooling / Heat
Pumps
observations
Positive
Attributes
The capacity and configuration of the system should
be sufficient for the home.
recommendations / observations
Central Air
Conditioning
·
Repair: Damaged insulation on
refrigerant lines should be repaired.
·
Improve: The outdoor unit of the air
conditioning system requires cleaning.
·
Monitor: Evidence of prior leakage
was observed at the condensate tray of the air conditioning
system.
limitations of Cooling / Heat
Pumps inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Window mounted air
conditioning units are not inspected.
·
The cooling supply adequacy
or distribution balance are not
inspected.
·
The air conditioning system could not be tested as
the outdoor temperature was below 60 degrees
F.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Insulation /
Ventilation
Attic
Insulation:
·Loose
Fiberglass/Mineral Wool in Main Attic
Exterior
Wall Insulation:
·R12
Fiberglass in Original Walls
Basement
Wall Insulation:
·None
Visible
Vapor
Retarders:
·Kraft
Paper
Roof
Ventilation:
·Roof
Vents
·Soffit Vents
Exhaust
Fan/vent Locations:
·Bathroom
Insulation /
Ventilation
observations
Positive
Attributes
This is a well insulated home.
recommendations / Energy saving Suggestions
limitations of Insulation /
Ventilation inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Insulation/ventilation type
and levels in concealed areas are not inspected. Insulation and vapor
barriers are not disturbed and no destructive tests (such as cutting
openings in walls to look for insulation) are performed.
·
Potentially hazardous
materials such as Asbestos and Urea Formaldehyde Foam Insulation (UFFI)
cannot be positively identified without a detailed inspection and
laboratory analysis. This
is beyond the scope of the inspection.
·
An analysis of indoor air
quality is not part of our inspection unless explicitly contracted-for
and discussed in this or a separate report.
·
Any estimates of insulation
R values or depths are rough average values.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Plumbing
Water
Supply Source:
·Public
Water Supply
Service
Pipe to House:
·Copper
Main
Water Valve Location:
·Front
Wall of Basement
Interior
Supply Piping:
·Copper
·Plastic
Waste
System:
·Public
Sewer System
Drain,
Waste, & Vent Piping:
·Plastic
Water
Heater:
·Gas
·Approximate
Capacity (in gallons): 50
·Manufacturer:
American ·Serial
Number: 9423122353
Fuel
Shut-Off Valves:
·Natural
Gas Main Valve At Meter
Other
Components:
·Pressure
Regulator on Main Line
Positive
Attributes
The plumbing system is in generally good
condition. The water
pressure supplied to the fixtures is reasonably good. A typical drop in
flow was experienced when two fixtures were operated
simultaneously. The
plumbing fixtures appear to have been well-maintained.
recommendations / observations
Water Heater
·
Monitor: Water heaters have a typical
life expectancy of 7 to 12 years. The existing unit is approaching or
has exceeded this age range. One cannot predict with certainty when
replacement will become necessary
Fixtures
·
Repair: The faucet in the upstairs
shared bathroom, left side is leaking.
·
Improve: Cracked, deteriorated and/or
missing bathtub enclosure grout and caulk should be improved.
limitations of Plumbing
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions:
·
Portions of the plumbing
system concealed by finishes and/or storage (below sinks, etc.), below
the structure, or beneath the ground surface are not inspected.
·
Water quantity and water
quality are not tested unless explicitly contracted-for and discussed in
this or a separate report.
·
Clothes washing machine
connections are not inspected.
·
Interiors of flues or
chimneys which are not readily accessible are not inspected.
·
Water conditioning systems,
solar water heaters, fire and lawn sprinkler systems, and private waste
disposal systems are not inspected unless explicitly contracted-for and
discussed in this or a separate report.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Interior
Wall
And Ceiling Materials:
·Drywall
Floor
Surfaces:
·Carpet
·Tile ·Vinyl/Resilient ·Wood ·Concrete
Window
Type(s) & Glazing:
·Casement
·Fixed
Pane
Doors:
·Wood-Hollow
Core
General Condition of
Interior Finishes
On the whole, the interior finishes of the home are
in average condition. Typical flaws were observed in some areas.
General Condition of
Windows and Doors
The majority of the doors and windows are good
quality.
recommendations / observations
Wall / Ceiling
Finishes
·
Monitor: Evidence of patching was
detected.
·
Monitor: Damage to the interior
finish was observed.
·
Monitor: Minor cracks were
noted.
·
Monitor: Typical drywall flaws were
observed.
Floors
·
Monitor: The carpet is stained (wear
and tear).
Windows
·
Repair: The window in the kitchen
dining area is broken.
Doors
·
Repair: Door to the master bedroom
should be adjusted as necessary to latch properly.
Basement Leakage
·
Monitor: No evidence of moisture
penetration was visible in the basement at the time of the inspection.
It should be understood that it is
impossible to predict whether moisture penetration will pose a problem
in the future. The vast majority of basement leakage problems
are the result of insufficient control of storm water at the surface.
The ground around the house should be sloped to encourage water to flow
away from the foundation. Gutters and downspouts should act to collect
roof water and drain the water at least five (5) feet from the
foundation or into a functional storm sewer. Downspouts that are clogged
or broken below grade level, or that discharge too close to the
foundation are the most common source of basement leakage. Please refer
to the Roofing and Exterior sections of the report for more
information.
In the event that basement leakage problems are
experienced, lot and roof drainage improvements should be undertaken as
a first step. Please beware of contractors who recommend expensive
solutions. Excavation, damp-proofing and/or the installation of drainage
tiles should be a last resort. In some cases, however, it is necessary.
Your plans for using the basement may also influence the approach taken
to curing any dampness that is experienced.
limitations of Interior
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions
·
Furniture, storage,
appliances and/or wall hangings are not moved to permit inspection and
may block defects.
·
Carpeting, window
treatments, central vacuum systems, household appliances, recreational
facilities, paint, wallpaper, and other finish treatments are not
inspected.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Appliances
Appliances
Tested:
·Electric
Range ·Microwave
Oven ·Dishwasher ·Waste
Disposer
Laundry
Facility:
·Dryer
Vented to Building Exterior ·Hot
and Cold Water Supply for Washer
·Waste
Standpipe for Washer
Other
Components Tested:
·Door
Bell
Positive
Attributes
The appliances are to be in generally good
condition. All appliances
that were tested responded satisfactorily. The kitchen and laundry
facilities are well organized.
recommendations / observations
limitations of Appliances
inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions
·
Thermostats, timers and
other specialized features and controls are not tested.
·
The temperature
calibration, functionality of timers, effectiveness, efficiency and
overall performance of appliances is outside the scope of this
inspection.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.
description of Fireplaces /
Wood Stoves
Fireplaces:
·Steel
Firebox
Vents,
Flues, Chimneys:
·Metal
Flue-Single Wall
Fireplaces /
Wood Stoves
observations
General Comments
On the whole, the fireplace and its components were
found to be in average condition. Typical flaws were observed in some
areas.
recommendations / observations
Fireplaces
·
Monitor/Repair: The hearth outside the
fireplace is damaged (broken/cracked tile).
limitations of Fireplaces /
Wood Stoves inspection
As we have discussed and as described in your
inspection contract, this is a visual inspection limited in scope by
(but not restricted to) the following conditions
·
The interiors of flues or
chimneys are not inspected.
·
Firescreens, fireplace doors, appliance gaskets and
seals, automatic fuel feed devices, mantles and fireplace surrounds,
combustion make-up air devices, and heat distribution assists (gravity
or fan-assisted) are not inspected.
·
The inspection does not
involve igniting or extinguishing fires nor the determination of
draft.
·
Fireplace inserts, stoves,
or firebox contents are not moved.
Please also refer to the
pre-inspection contract for a detailed explanation of the scope of this
inspection.